DENON AVR/AVC control protocol
Ver. 4.0
Application model : AVR-3805/AVC-3890
Application terminal : RS-232C
Connector specification
Connector type : DB-9pin female type, slave straight connection (DCE type)
( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
Communication format :
Synchronous system : Tone step synchronization
communication system : A half duplex
Communication speed : 9600bps
Character length : 8 bits
Parity control : None
Start bit : 1 bit
Stop bit : 1 bit
Communication procedure : Non procedural
Communication data length : 135 bytes (maximum)
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - Connector specification

- 1 - DENON AVR/AVC control protocol Ver. 4.0 Application model : AVR-3805/AVC-3890 Application terminal : RS-232C Connector specification Connec

Page 2 - Protocol specification

- 10 - EVENT(or RESPONSE) and PARAMETER list EVENT PARAMETER function example *RES. PW ON POWER ON/STANDBY change PWON<CR> ST

Page 3

- 11 - EVENT PARAMETER function example *RES. ZM ON MAIN-ZONE ON/OFF change ZMON<CR> OFF ZMOFF<CR> Z1 PHONO MU

Page 4 - Others

- 12 - EVENT PARAMETER function example *RES. TF ****** (6 digits) TUNER Frequency change TF105000<CR> --- ****.** kHz at AM

Page 5 - COMMAND and PARAMETER list

- 13 - EVENT PARAMETER function example *RES. MS DIRECT SURROUND mode change MSDIRECT<CR> PURE DIRECT MSPURE DIRECT<CR&

Page 6

- 14 - EVENT PARAMETER function example *RES. DTS NEO:6 CINEMA MSDTS NEO:6 C<CR> DTS NEO:6 MUSIC MSDTS NEO:6 M<CR>

Page 7

- 15 - *RES. : NOT returns '? ' parameters as RESPONSE. EVENT PARAMETER function example *RES. PS ROOM EQ:NORMAL ROOM EQ mode chan

Page 8

- 2 - Protocol specification The following three data forms is defined. COMMAND : The message sent to a system(AVR/AVC) from a controller(Touc

Page 9

- 3 - The example of a command * <CR> is the meaning of 0x0D. SIDVD<CR> : Select Input source DVD MSTHX SURROUND EX<CR>

Page 10

- 4 - Others A) COMMAND is receivable also during transmission of EVENT. B) Since CHANNEL VOLUME changes simultaneously when the SURROUND MODE c

Page 11

- 5 - COMMAND and PARAMETER list COMMAND PARAMETER function example PW ON POWER ON/STANDBY change PWON<CR> STANDBY PWST

Page 12

- 6 - COMMAND PARAMETER function example CV SB UP ---SURROUND BACKch (SBch 1SP) CVSB UP<CR> SB DOWN CVSB DOWN<CR&

Page 13

- 7 - COMMAND PARAMETER function example Z2 PHONO MULTI ZONE-2 mode set , and select source at AVR-3805 Z2PHONO<CR> | --

Page 14

- 8 - EVENT PARAMETER function example MS DIRECT SURROUND mode set MSDIRECT<CR> PURE DIRECT MSPURE DIRECT<CR>

Page 15

- 9 - TF, TP, TM COMMAND : '*' parameters can NOT operate when INPUT source isn’t TUNER. EVENT PARAMETER function example MS MPEG2